ree

There are not many reliable field GCs available on the market. Selecting the right compound-specific field GC for VOC screening and measurement can make a significant difference in capturing accurate, real-time air data. At AirLogics, we focus on providing solutions that simplify the detection process while maintaining high-quality standards. Our field gas chromatograph (GC) is designed to provide efficient, reliable results for volatile organic compounds detection, making it an essential tool for professional monitoring services. Its design and performance are optimized for a variety of applications, allowing our clients to trust the data we provide in multiple monitoring scenarios.


Compact Design for Practical Deployment


Our field GC is crafted for mobility and ease of use. Measuring only 36 x 30 x 15 cm and weighing 7 kg, it integrates an auto-sampling unit, carrier gas system, separation unit, detection unit, and rechargeable battery into a single portable system. This compact form factor allows our team at AirLogics to deploy the field GC quickly across different sites without compromising on performance or accuracy.


This portability does not just reduce transportation challenges; it also minimizes setup time, making the device ideal for VOC screening projects that require real-time data and frequent relocations or urgent sampling. For clients working across multiple locations, the ability to deploy a single device rapidly can lead to faster results and more consistent data quality. The design also ensures that the system remains stable during transport, preventing calibration errors or damage.


Cutting-Edge Detection Technology


The AirLogics field GC employs a microfluidic design coupled with a patented MEMS-based Photoionization Detector, the NovaPID. This combination ensures high sensitivity with minimal system dead volume, producing sharp peaks and precise results. By using this advanced technology, AirLogics ensures that volatile organic compounds detection is efficient, accurate, and consistent across all monitoring operations.

In practice, this means small or complex compounds are not overlooked. The technology reduces interference from surrounding air components, delivering clear, reliable measurements even in challenging conditions. For projects where high accuracy is critical, our device captures subtle variations in compound levels that traditional equipment may miss.


Broad Detection Capabilities


Our field GC clients can detect over 300 organic compounds, with ionization potentials below 10.6 eV. The device offers flexible detection ranges, covering trace levels from 1 ppb to 1 ppm and higher concentrations from 200 ppb to 200 ppm. This broad spectrum allows AirLogics to provide data that meets varied project requirements without sacrificing reliability.


For example, some projects require monitoring extremely low levels of volatile organic compounds, while others may involve higher concentrations of common industrial compounds. Our field GC adapts to both needs effortlessly. This versatility makes it suitable for long-term monitoring campaigns, where the nature and concentration of compounds may change over time. It allows our team to adjust methods on the fly and still provide actionable results quickly.


Quick and Efficient Analysis


Time is critical when capturing air quality data. We can analyze samples within minutes, significantly faster than traditional gas chromatographs. For example, BTEX compounds can be separated in less than three minutes. This rapid analysis capability allows AirLogics to deliver timely and actionable data for all monitoring assignments.

The speed of analysis also helps clients who need immediate insights for planning or reporting purposes. Quick turnaround does not compromise quality, as each sample is processed with precise calibration, ensuring that results remain accurate while minimizing wait time. For larger projects requiring multiple samples, this efficiency translates into significant time savings and allows for more comprehensive monitoring coverage.


Intuitive Operation


Our field GC is straightforward. It connects to a laptop via USB, offering two modes: a quick test with minimal input and a traditional mode with fully editable parameters. Built-in methods for target compounds simplify testing, enabling AirLogics to provide seamless monitoring services without extensive setup procedures.  Reliable data is delivered in real-time, supporting projects that require detailed information for decision-making.


This user-friendly approach ensures that even in high-pressure situations, our team can focus on the data rather than struggling with equipment. Adjustments to testing protocols can be made without requiring complicated recalibration or specialized technical skills. This design is particularly valuable for projects with varied sampling conditions, where quick changes in method are often necessary.


Versatile Sampling Options


Flexible sampling is critical for projects involving multiple types of monitoring, including indoor air assessments, sub-slab soil gas investigations, screening for your next monitoring well location, perimeter air quality monitoring, and community air monitoring, or direct sampling from containers. This versatility reduces the logistical challenges of managing multiple instruments and simplifies the monitoring workflow for our clients.


Ending Note:


The AirLogics field GC stands out as a dependable and highly capable compound-specific field GC for VOC measurement device that delivers precise, real-time, rapid results. Its compact design, advanced detection technology, wide detection range, and flexible sampling options make it an essential tool for volatile organic compounds detection. At AirLogics, we utilize the GC to provide thorough, accurate monitoring, giving our clients the confidence to make informed decisions based on reliable data. With this device, organizations can enhance their monitoring capabilities and achieve superior outcomes in volatile organic compound testing.


FAQs:


1. What is the AirLogics Field GC used for?


The AirLogics Field GC is used for accurate real-time detection of volatile organic compounds in air.


2. How portable is the AirLogics Field GC?


It is compact, weighing 7 kg, with integrated sampling and battery systems for easy deployment.


3. Can the P100 detect multiple compounds?


Yes, it can detect over 300 organic compounds across trace and higher concentrations.


4. How fast does the AirLogics Field GC provide results?


Analysis takes only a few minutes, enabling rapid, actionable data for monitoring projects.


5. Is the AirLogics Field GC easy to operate?


Yes, it connects via USB to a laptop, with quick or traditional test modes available.

 
 
 